S01 Button type is snap action and bimetallic thermostat, Bimetal trips off or on quickly to open or close the circuit when temperature reaches the prescribed value.
Special Features |
* Small size and easy for mounting;
* Low current sensitivity, no large temperature difference due to over current;
* Precise temperature control.
Electrical Specifications |
250V AC : 3A
125V AC : 6A
24V DC: 6A
Contact Resistance: <30mΩ
Dielectric Strength: 2KV
Technical Parameters |
Operating Temperature | 60~220℃, A specification for each 5℃ |
Operating Temperature Tolerance | ±5℃ |
Reset Temperature | Less than 1/3 of operating temperature |
Reset Temperature Tolerance | ±15℃ |
Application |
Transformer
Coil
Curtain Motor
Washing Machine Motor
Certification: |
CQC:17002172427
UL&CUL:E309992
TUV:R 50383352 0001
VDE:40048046
Dimensional Drawings |
Series Application |
FAQ |
1. What is the warranty period of your thermal protector?
The warranty period of thermal protector we promised is not a specific time, like how many days, months or years, but the action cycles of thermal protector. Normally the life cycles ranges from 10,000 cycles to 100,000 cycles according to different models and working capacity. It is one of the most important parameters of thermal protectors. Customers can find it in the specification of different models.
The life cycles we mentioned here are only for working under rated current and voltage. If the working condition changed, the final life endurance would be also different.
2. How should I select the correct action temperature of thermostat?
The action temperature selection of a thermostat should be based on the application:
Measure the temperature of the position where the thermostat would be mounted;
Setting the temperature range of application;
Select the temperature of a thermostat. The current flowing through thermostat need to be considered when selecting this temperature. If this thermostat is used for heat protection, the action value should be above the normal working temperature, but lower than the temperature limit of other components to be damaged.
3. What’s the difference between Normally Closed thermal switch and normally open thermal switch?
Normally closed thermal switch means that the contacts of thermal switch normally remain closed. When temperature increases to the set value, the contacts would open and cut the circuit OFF.
Normally open thermal switch means that the contacts of thermal switch normally remain open. When temperature rises, the contacts would close and connect the circuit ON.
We now have several models that both Normally Open and Normally Close type are optional, like 17AME, TS01, KW, KSD301, 3MPE, and so on.
Contact Information
Company Name: Yangzhou Wuyue Electric Co.,Ltd
Address:Building D, Software Information Industrial Park, No.2 Huaijiang Avenue, Baoying County, Jiangsu Province, China
Contact: Lorena Qiao
Mobile: +86 153 6641 6606 / 189 2191 2633
Tel: +86 514 88986588
Fax:+86 514 8898 6599
http://https://wuyuecn.en.alibaba.com
Email: sales01@wuyuetech.com
CATEGORIES
CONTACT US
Building D, Software information Industrial Park, No. 2 Huaijiang Avenue, Baoying County, Yangzhou City, Jiangsu Province, China
NEWSLETTER