* Rated Current: 3A~50A
* Rated Voltage:125/250VAC 50VDC
* Short-Circuit Test:250VAC*1000AM 250VAC*200A
* Hi-pot test:1,500VAC/min
* Overload capacity:10 times rated current
AR2 Series plastic shell current overload protector

* Rated Current: 3A~50A
* Rated Voltage:125/250VAC 50VDC
* Short-Circuit Test:250VAC*1000AM 250VAC*200A
* Hi-pot test:1,500VAC/min
* Overload capacity:10 times rated current
* Voltage degradation:Less than 0.25V
* Insulation Resistance: More than 500MΩ
* Terminal Temperature rise: Stable at 25℃,
Temperature Rise <65K at 100% rated current
* Reset Time: in 60 seconds
* Reset Method: Manual
* Test Standard(25℃)
100% Rated Current: No trip Off
150% Rated Current:Trip in 1 hour
200% Rated Current:4~40 seconds trip off
300% Rated Current:1.2~15 seconds trip off
| Derating Factor | |
| Temperature | Rating Amp |
| 60℃ | *0.6 |
| 50℃ | *0.7 |
| 40℃ | *0.8 |
| 30℃ | *0.9 |
| 25℃ | *1.0 |
| 20℃ | *1.1 |
| 10℃ | *1.3 |
| 0℃ | *1.5 |
| Max Resistance V.S. Current Rating at 25℃ | |
| Current Rating In Amp | Maximum Resistance In Ohms |
| 2~4 Amp | <0.05 |
| 5~6 Amp | <0.04 |
| 7~8 Amp | <0.025 |
| 9~11 Amp | <0.02 |
| 12~13 Amp | <0.01 |
| 14~16 Amp | <0.008 |
| 17~25 Amp | <0.007 |
| Application |
Lower power generator
Air compressor
Compressor
Electric car
Power tools
Extension cable
Transformer
| Dimensional Drawing |