* Rated Current: 3A~50A
* Rated Voltage:125/250VAC 50VDC
* Short-Circuit Test:250VAC 1000A
* Hi-pot test:1,500VAC/min
* Overload capacity:10 times rated current
98 Series 3A-50A overload protector
* Rated Current: 3A~50A
* Rated Voltage:125/250VAC 50VDC
* Short-Circuit Test:250VAC 1000A
* Hi-pot test:1,500VAC/min
* Overload capacity:10 times rated current
* Voltage degradation:Less than 0.25V
* Insulation Resistance: More than 500MΩ
* Terminal Temperature rise: Stable at 25℃,
Temperature Rise <65K at 100% rated current
* Reset Time: in 60 seconds
* Reset Method: Manual
* Test Standard(25℃)
100% Rated Current: No trip Off
150% Rated Current:Trip in 1 hour
200% Rated Current:4~40 seconds trip off
300% Rated Current:1.2~15 seconds trip off
Derating Factor | |
Temperature | Rating Amp |
60℃ | *0.6 |
50℃ | *0.7 |
40℃ | *0.8 |
30℃ | *0.9 |
25℃ | *1.0 |
20℃ | *1.1 |
10℃ | *1.3 |
0℃ | *1.5 |
Max Resistance V.S. Current Rating at 25℃ | |
Current Rating In Amp | Maximum Resistance In Ohms |
2~4 Amp | <0.05 |
5~6 Amp | <0.04 |
7~8 Amp | <0.025 |
9~11 Amp | <0.02 |
12~13 Amp | <0.01 |
14~16 Amp | <0.008 |
17~25 Amp | <0.007 |
26~35 Amp | <0.006 |
36~50 Amp | <0.005 |
Lower power generator
Air compressor
Compressor
Electric car
Power tools
Extension cable
Transformer
1. Test Condition:
Unless otherwise specified, the test shall be carried out at a normal temperature of 20-30 ° C, and the current protector may be installed at any position of the test instrument.
2. Humidity And Heat Test
The overload protector shall be able to withstand the constant damp heat test method (Ca). The severity of the test shall be 48 h. The insulation resistance after the damp heat test shall not be less than 2 MΩ. The performance after the test shall meet the following conditions:
A:The shape of test sample should not be deformed significantly;
B:The electrical strength shall comply with Item 3.2 and the test voltage shall be 80% of the original test voltage.
3. Anti-seismic Property
The overload protector should be able to withstand an amplitude of 0.35mm, a frequency change of 10-50HZ, a change period of 3-5 times/min, and a clamping direction of X. Y. Z. After 1.5h of each test, the performance should meet the following requirements:
A:The rated disconnection should be within the initial value;
B:The test sample shall be free of deformation and damage, and the terminals shall not loosen and fall off.
4. Drop Resistance
A:The rated disconnection should be within the initial value;
B:The contact resistance should be within the setting value;
C:The test sample shall be free of deformation and damage, and the terminals shall not loosen and fall off.
CATEGORIES
CONTACT US
Building D, Software information Industrial Park, No. 2 Huaijiang Avenue, Baoying County, Yangzhou City, Jiangsu Province, China
NEWSLETTER